Navien General: Replace the sediment pre-filter cartridge

Updated · by Aurora Star Tech Inc.

Replace the sediment pre-filter cartridge on a Navien general: Procedure for changing the sediment pre-filter cartridge. Replace about every 6 months, or sooner if flow or pressure drops or the REPLACE FILTER icon lights.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC Series sediment pre-filter

Common causes of replace the sediment pre-filter cartridge

  • Flow or pressure loss at fixtures may mean the cartridge needs changing before the indicator comes on.
  • Water quality can shorten cartridge life.

How to fix replace the sediment pre-filter cartridge: step by step

  1. Unplug the WEC power cord (power off). An error will block filter replacement if power is still on.
  2. Close the inlet and outlet valves.
  3. Open the bypass valve.
  4. Press the red pressure release button on the sediment pre-filter housing cover. If there is no button, close bypass, open outlet and a nearby cold faucet, then close outlet, open bypass and close the faucet. Do not drain the whole plumbing.
  5. Unscrew the housing with the filter housing wrench.
  6. Remove and discard the used cartridge.
  7. Clean inside the housing.
  8. Install the new cartridge with the top gaskets in place and centered, then tighten with the wrench.
  9. Close bypass and service valves, then open inlet and outlet valves.
  10. Press the red pressure release button to purge air from the housing.
  11. Plug the power cord in. The WEC starts Auto Flushing and then goes to standby.
  12. Reset the sediment pre-filter use period: press and hold Back, OK and Next for 3 seconds (see 3.7, p. 36).
  13. Keep the inlet and outlet plugs in place until installation. Do not leave internals exposed to air for more than 4 hours.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC Series Service Manual, p. 42-43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.