Navien General: Replace the TDS sensor for the product/regeneration water pipe

Updated · by Aurora Star Tech Inc.

Replace the TDS sensor for the product/regeneration water pipe on a Navien general: The CIP tank must come out to reach this sensor. Be careful with CIP solution: a spill can corrode the unit, and if it contacts skin or eyes, flush with running water right away.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC600

How to fix replace the tds sensor for the product/regeneration water pipe: step by step

  1. Turn off the feedwater supply.
  2. Disconnect the power supply from the WEC.
  3. Remove the 2 screws on each side of the front cover and set the cover aside.
  4. Remove the 4 screws from the CIP tank assembly and pull the tank out of the WEC. Avoid spilling the solution.
  5. Place the CIP tank on a flat, clear surface.
  6. From the back of the CIP tank, disconnect the water level sensor connector and CIP dosing pump connector from the harness.
  7. Disconnect the TDS sensor connector from the harness.
  8. Loosen the sensor nut with a wrench and remove the TDS sensor assembly from the Y-adapter.
  9. Install the new TDS sensor assembly on the Y-adapter and tighten the nut with a wrench.
  10. Connect the TDS sensor connector to the harness.
  11. From the back of the CIP tank, reconnect the water level sensor and CIP dosing pump connectors to the harness.
  12. Install the CIP tank in the WEC and secure with 4 screws.
  13. Align the front cover with the WEC and secure each side with 2 screws.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC service manual, p. 97-98. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.