General: Monthly check

Updated · by Aurora Star Tech Inc.

Monthly check on a general: Monthly steam boiler check. Quick, but it saves boilers. Water level, relief and the low water cutoff are what keep a steam boiler from running dry. Hot water and steam can scald, so work with care.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Common causes of monthly check

  • Water level too high or too low in the sight glass
  • Relief lever not discharging
  • Low water cutoff not tripping on drain
  • Sediment in the glass or control making readings unreliable

How to fix monthly check: step by step

  1. Check the sight glass, it should sit at 1/3 to 1/2.
  2. If it's high, drain some off.
  3. If it's low but visible, add water.
  4. If none is visible or pressure is high, shut it off, let it cool, then add water.
  5. Test the relief lever and confirm it discharges.
  6. Drain to confirm the LWCO trips.
  7. Hot water and steam can scald, so work with care.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes Trane General codes

Source: General HVAC service practice — verify per model. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.