Navien General: Filling the Navien CIP solution

Updated · by Aurora Star Tech Inc.

Filling the Navien CIP solution on a Navien general: Fill the CIP tank safely with Navien CIP solution.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC600

How to fix filling the navien cip solution: step by step

  1. Wear proper PPE and follow the Safety Data Sheet.
  2. Remove the screws on both sides of the front cover and take the cover off.
  3. Remove the lid from the CIP tank.
  4. Insert a plastic funnel into the CIP tank inlet.
  5. Fill slowly to avoid spills. Do not use solution if solids are visible.
  6. Fill the tank to the level shown, remove the container, and close the lid.
  7. Wipe up any spill right away with a clean, wet towel.
  8. Close the front cover and tighten both screws.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC service manual, p. 23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.