Navien General: Installing inlet and outlet water lines
Installing inlet and outlet water lines on a Navien general: Connect the water lines through the bypass and service valves.
Applies to: WEC600
How to fix installing inlet and outlet water lines: step by step
- Shut off the water supply before connecting the product.
- Remove the L-clips, caps and O-rings from the inlet and outlet. Cover the cap with a dry towel while removing it, as some water may come out.
- Check the strainer in the inlet adapter. Clean it if it is clogged.
- Install the filters, inlet and outlet valves, bypass valve and regulator (if needed) per the piping diagram.
- Place O-rings on the inlet and outlet, fit the adapters, and secure them with the L-clips.
- Do not over-tighten filter connections and support the piping so it puts no stress on the valves.
- Check all connections, then check for leaks as described in section 2.13.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC service manual, p. 19-20. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.