Navien General: Booster pump installation
Booster pump installation on a Navien general: A booster pump can raise pressure at the point of use. It must not push excess pressure into the WEC.
Applies to: WEC600
How to fix booster pump installation: step by step
- Use a flow-sensing, automatic-operating booster pump.
- Confirm shut-off pressure at zero flow does not exceed 8.5 bar (128 psi).
- Install the pump downstream of the carbon block filter.
- Install a check valve between the carbon block filter and the booster pump.
If the unit shows an error code, look it up: Navien General codes
Source: WEC Series service manual, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.