Navien General: Replacing the power assembly
Replacing the power assembly on a Navien general: Replace the power assembly base and upper case with new parts.
Applies to: WEC600
How to fix replacing the power assembly: step by step
- Turn off the feedwater supply and disconnect power
- Remove the front cover, top cover and power assembly upper case
- Remove the 6 connectors from the PCB (AC-INPUT, PUMP, CN2, FAN, DC1-OUT and DC2-OUT)
- Remove the 4 screws securing the power assembly base and lift off the base
- Install the new power assembly base and secure with 4 screws
- Connect the 6 connectors to the PCB (AC-INPUT, PUMP, CN2, FAN, DC1-OUT and DC2-OUT)
- Install the new power assembly upper case with 4 screws
- Place the top cover on the WEC and connect the 4 connectors to the back of the main panel
- Secure the 2 screws to the front and 2 to the back of the top cover
- Align the front cover screw holes and secure each side with 2 screws
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC600 service manual, p. 83-85. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.