Navien General: Replacing the TDS sensor on the inlet water pipe assembly
Replacing the TDS sensor on the inlet water pipe assembly on a Navien general: Removes the TDS sensor from the T-adapter on the inlet water pipe assembly. Part of the inlet pipe section, so some steps in the manual are printed on the following page.
Applies to: WEC600
How to fix replacing the tds sensor on the inlet water pipe assembly: step by step
- Shut off the feedwater supply.
- Disconnect power to the WEC.
- Remove the 2 screws on each side of the front cover and set the cover aside.
- Remove the ground wire screw from the WEC case and unplug the circulation pump connector from the harness.
- Remove the pump adapters from the circulation pump.
- Remove the 4 pump bracket screws and lift the circulation pump assembly out of the WEC.
- Unclip the inlet water pipe assembly and pull out the CIP solenoid valve assembly.
- Unplug the connector from the CIP solenoid valve.
- Use a wrench to remove the TDS sensor connector from the harness, then remove the TDS sensor from the T-adapter.
- Install the new TDS sensor on the T-adapter and connect its connector to the harness.
- Reinstall the CIP solenoid valve assembly, clip it to the inlet water pipe, and secure the pump bracket with 4 screws.
- Fix the ground wire to the WEC case, connect the circulation pump connector, and reinstall the pump adapters.
- Align the front cover with the WEC and secure each side with 2 screws.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC Series service manual, p. 104-106. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.