Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code 076: Abnormal close of the product water valve (General)

Updated · by Aurora Star Tech Inc.

Navien error code 076 on a general means: Abnormal close of the product water valve. It is also called Navien diagnostic code 076.

High severityGeneralWEC Series

Homeowner? What Navien code 076 means for you

Call a technician Your heating or cooling system is reporting: Abnormal close of the product water valve. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code 076 mean?

Product water valve did not close correctly during install check.

Applies to: WEC600

Common causes of Navien code 076

  • Product water valve
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien General codes

CodeMeaning
070Water connection
071Abnormal faucet opening
072Abnormal close of the bypass valve
073Abnormal close of the main valve
074Abnormal open of the main valve
075Abnormal open of the bypass valve
077Abnormal close of the regeneration valve
078Abnormal close of the regeneration valve
079Abnormal open of the regeneration valve
080Abnormal open of the regeneration valve
081Abnormal open of the product water valve
082Abnormal open of the product water valve

All Navien General error codes →

Navien code 076: homeowner questions

What does Navien code 076 mean?

Abnormal close of the product water valve. Product water valve did not close correctly during install check.

Is it safe to keep using my heating or cooling system with code 076?

It depends on the cause. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code 076 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code 076 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code 076 near me?

Aurora Star Tech Inc. repairs Navien heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Navien WEC service manual, p. 54. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977