Rheem Furnace: Furnace short cycles or does not hold setpoint
Furnace short cycles or does not hold setpoint on a Rheem furnace: Rheem 802PA furnaces and matching 80MDP models: heat cycles end early or the room temperature drifts away from the setpoint. Applies to (-)802PA050314MSA, (-)802PA075417MSA, (-)802PA100521MSA, (-)802PA125524MSA, (-)802PA150524MSA.
Applies to: (-)802PA050314MSA, (-)802PA075417MSA, (-)802PA100521MSA, (-)802PA125524MSA, (-)802PA150524MSA and matching (-)(-)80MDP models
Common causes of furnace short cycles or does not hold setpoint
- Thermostat in a bad spot, so it satisfies before the house does
- Heat anticipator set wrong
- Limit opening and closing on low airflow, which shows as code 22
- Furnace oversized for the load
How to fix furnace short cycles or does not hold setpoint: step by step
- Check thermostat location, because registers, sunlight, and pipes or wires in the wall behind it all fool it
- Check the heat anticipator setting; an isolation relay may be needed on some thermostats
- See whether a limit is cycling (code 22), and check the filter, ducts and blower speed because restricted air heats the exchanger fast
- Measure temperature rise and compare it to the rating plate range
- Verify furnace size against the load, since an oversized unit short cycles even when everything else is right
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
Rheem 90RJ/90TJ 90 Plus
90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12
96MDV
96MDV06096MDV07096MDV08596MDV100
R96V/96MDV
R95P
R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA
Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)
R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA
RGPE/RGLE
RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Rheem (-)GRC/(-)GTC 90 Plus
RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS
Rheem RGRM/RGTM 90 Plus
RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10
Source: Rheem (-)802P/(-)(-)80MDP Installation Instructions 92-24161-146-02, Diagnostics Flowchart (Figure 33), p.51. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.