Rheem Furnace: Test communication with the LEARN button (RGPE/RGLE)
Test communication with the LEARN button (RGPE/RGLE) on a Rheem furnace: Holding LEARN makes the green RX LED blink rapidly if the control is trying to communicate. No blinking means communication cannot be established (check wires 1 and 2 at connector J9 are not reversed).
Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces
How to fix test communication with the learn button (rgpe/rgle): step by step
- Press and hold the LEARN button for two seconds
- Watch the green RX LED: a short burst of rapid blinking = attempting communication
- No blinking: check the 1, 2, R and C wiring between furnace, thermostat and condenser
If the unit shows an error code, look it up: Rheem Furnace codes
Models
RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Source: RGPE Learn Button, p.42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.