Updated · by Aurora Star Tech Inc.

Test communication with the LEARN button (RGPE/RGLE) on a Rheem furnace: Holding LEARN makes the green RX LED blink rapidly if the control is trying to communicate. No blinking means communication cannot be established (check wires 1 and 2 at connector J9 are not reversed).

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces

How to fix test communication with the learn button (rgpe/rgle): step by step

  1. Press and hold the LEARN button for two seconds
  2. Watch the green RX LED: a short burst of rapid blinking = attempting communication
  3. No blinking: check the 1, 2, R and C wiring between furnace, thermostat and condenser
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Source: RGPE Learn Button, p.42. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.