Rheem Furnace: Inducer runs 60 s then shuts off for 5 minutes, or runs continuously
Inducer runs 60 s then shuts off for 5 minutes, or runs continuously on a Rheem furnace: Inducer cycles on 60 s / off 5 min, or never stops, without the furnace lighting.
Applies to: Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus condensing gas furnaces
Common causes of inducer runs 60 s then shuts off for 5 minutes, or runs continuously
- Open limit or limit circuit
- Intermittent pressure switch
- Vent restriction, excessive vent length or too-small vent
- Blocked heat exchanger
How to fix inducer runs 60 s then shuts off for 5 minutes, or runs continuously: step by step
- Check the STATUS LED blink code first.
- Check for an open limit or limit circuit.
- Check for intermittent pressure switch operation.
- Check the vent for restrictions and confirm vent length and diameter are within limits.
- Check for a blocked heat exchanger.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
Rheem 90RJ/90TJ 90 Plus
90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12
R95P
R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA
Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)
R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA
RGPE/RGLE
RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Rheem (-)GRC/(-)GTC 90 Plus
RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS
Rheem RGRM/RGTM 90 Plus
RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10
Source: Rheem (-)GRC/(-)GTC Installation Instructions 92-24161-88-00, Figure 56 IFC Troubleshooting Guide, p.54 (printed); Rheem 90RJ/90TJ Installation Instructions 92-24161-32-08, Figure 53, p.54. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.