Rheem Furnace: Inducer runs 60 seconds then off for 5 minutes

Updated · by Aurora Star Tech Inc.

Inducer runs 60 seconds then off for 5 minutes on a Rheem furnace: R95P (Rheem/Ruud (-)95P, 95% single-stage). Inducer runs 60 seconds, drops out for 5 minutes. Pressure switch not proving. Look at the vent and the switch circuit, in that order.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Rheem/Ruud (-)95P series 95% single-stage condensing gas furnace (R95PA)

Common causes of inducer runs 60 seconds then off for 5 minutes

  • Blocked vent or intake
  • Water in the pressure switch hoses
  • Wind buffeting the vent termination
  • Bad pressure switch

How to fix inducer runs 60 seconds then off for 5 minutes: step by step

  1. Check the pressure switch, hoses and wires.
  2. Look for a blocked vent or intake, excess vent length or elbows, and a blocked heat exchanger.
  3. Check the switch and hoses for water; blow them out and fix whatever is letting it in.
  4. Check the inducer is wired correctly.
  5. Look for wind opening the switch, or intermittent switch operation. Do not jump the switch.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

96V

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

Rheem 90RJ/90TJ 90 Plus

90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12

96MDV

96MDV06096MDV07096MDV08596MDV100

R96V/96MDV

96MDV115D50A

R95P

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA

Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)

R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA

RGPE/RGLE

RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Rheem (-)GRC/(-)GTC 90 Plus

RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS

Rheem RGRM/RGTM 90 Plus

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Source: Rheem R95P Installation Instructions (ManualsLib 989115), Figure 49 IFC Troubleshooting Guide, p.96 (PDF p.100). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977