Rheem Furnace: Inducer (draft motor) does not start on heat call
Inducer (draft motor) does not start on heat call on a Rheem furnace: R95P: no inducer on a heat call.
Applies to: Rheem/Ruud (-)95P series 95% single-stage condensing gas furnace (R95PA)
Common causes of inducer (draft motor) does not start on heat call
- No 24 V on W
- Limit circuit open
- Inducer or capacitor failed
- Wiring IFC to inducer
How to fix inducer (draft motor) does not start on heat call: step by step
- Set fan to AUTO and call for heat (set point more than 10 F above room).
- Check 24 V on W at the IFC; if none, check thermostat mode, battery, wires.
- Check for an open limit or limit circuit.
- Check line voltage at the inducer and on the IFC inducer pins.
- Check wires/connections IFC to inducer and inducer capacitor (90+).
- Check IFC last - most failures are not the IFC.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
Rheem 90RJ/90TJ 90 Plus
90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12
R95P
R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA
Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)
R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSA
RGPE/RGLE
RGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR
Rheem (-)GRC/(-)GTC 90 Plus
RGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS
Rheem RGRM/RGTM 90 Plus
RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10
Source: Rheem R95P Installation Instructions (ManualsLib 989115), Figure 49 IFC Troubleshooting Guide, p.96 (PDF p.100). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.