Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Error Code 5 flashes: Flame sensed with no call for heat (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code 5 flashes on a furnace means: Flame sensed with no call for heat. It is also called Goodman diagnostic code 5 flashes.

Critical severityFurnaceGoodman/Amana *MES9 single-stage

Homeowner? What Goodman code 5 flashes means for you

Stop and call Your furnace is reporting: Flame sensed with no call for heat. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code 5 flashes mean?

The control sees flame while the gas valve should be closed. The inducer and circulator blower run continuously and the furnace will not run.

Applies to: GMES9, GCES9, AMES9, ACES9, VMES9, VCES9 (single stage, 92% and 96%)

Common causes of Goodman code 5 flashes

  • Short to ground in the flame sense circuit or wire
  • Flame lingering in the burners
  • Slow-closing gas valve
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code 5 flashes

Show all 57 models

ACES96ACES960403BNAAACES960603BNAAACES960804CNAAACES961005CNAAACES961205DNAAAMES92AMES96AMES920403ANAAAMES920603BNAAAMES920803BNAAAMES920804CNAAAMES920805CNAAAMES921004CNAAAMES921005CNAAAMES921205DNAAAMES960403ANAAAMES960603BNAAAMES960803BNAAAMES960804CNAAAMES960805CNAAAMES961005CNAAAMES961205DNAAGCES96GCES960403BNAAGCES960603BNAAGCES960804CNAAGCES961005CNAAGCES961205DNAAGMES92GMES96GMES920403ANAAGMES920603BNAAGMES920803BNAAGMES920804CNAAGMES920805CNAAGMES921004CNAAGMES921005CNAAGMES921205DNAAGMES960403ANAAGMES960603BNAAGMES960803BNAAGMES960804CNAAGMES960805CNAAGMES961005CNAAGMES961205DNAAVCES96VCES960403BNAAVCES960603BNAAVCES960804CNAAVCES961005CNAAVMES96VMES960403ANAAVMES960603BNAAVMES960803BNAAVMES960804CNAAVMES961005CNAA

Other Goodman Furnace codes

CodeMeaning
1 flashLockout - three failed ignition tries
1ACCooling, low stage
2 flashesPressure switch stuck closed
2ACCooling, high stage
3 flashesPressure switch stuck open
4 flashesPrimary or auxiliary limit open
6 flashesRollout limit open or control fuse blown
7 flashesLow flame signal
8 flashesIgniter relay fault
9 flashesTwinning fault
10 flashesOpen fuse - no 24 V at the control
11 flashesIgniter open

All Goodman Furnace error codes →

Goodman code 5 flashes: homeowner questions

What does Goodman code 5 flashes mean?

Flame sensed with no call for heat. The control sees flame while the gas valve should be closed. The inducer and circulator blower run continuously and the furnace will not run.

Is it safe to keep using my furnace with code 5 flashes?

No. Code 5 flashes is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Goodman code 5 flashes myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Goodman code 5 flashes near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Goodman Service and Troubleshooting GMES9*/GCES9*/AMES9*/ACES9*/VMES9*/VCES9* (RS6612016r3) , Troubleshooting Chart p.52; LED table p.44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair