Navien Air Conditioner: Sensor and valve reference (T3, T4, T5, T7, Tfin, PT, PEV)
Sensor and valve reference (T3, T4, T5, T7, Tfin, PT, PEV) on a Navien air conditioner: Reference list of what each sensor or valve controls. Use it to understand protection and control behavior.
Applies to: NAA17V36-24K/36K and NAA17V60-48K/60K
How to fix sensor and valve reference (t3, t4, t5, t7, tfin, pt, pev): step by step
- T3 (outdoor coil temperature): high temperature protection and outdoor fan control.
- T4 (ODU ambient temperature): limits maximum compressor frequency.
- T5 (compressor discharge temperature): high discharge temperature and low superheat protection.
- T7 (control board pipe temperature): control board condensation prevention.
- Tfin (IPM condenser temperature): high IPM temperature protection.
- PT (pressure transducer): senses evaporating pressure, controls compressor frequency, and provides low pressure protection.
- PEV (pressure equalizer valve): balances system pressure before compressor start-up.
If the unit shows an error code, look it up: Navien Air Conditioner codes
More other tips for air conditioner
Source: Navien NAA air conditioner service manual, pp. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.