Navien Air Conditioner: Decommissioning and labeling
Decommissioning and labeling on a Navien air conditioner: Before decommissioning, the technician must be familiar with the equipment and power must be available.
Applies to: NAA17V36-24K/36K and NAA17V60-48K/60K
How to fix decommissioning and labeling: step by step
- Isolate the system electrically.
- Pump down the system if possible, or manifold the system to recover from all sections.
- Take an oil and refrigerant sample first if the refrigerant will be reused.
- Do not reuse recovered refrigerant until it has been cleaned and checked.
- Once emptied, label the equipment as dated, signed, and containing flammable refrigerant.
If the unit shows an error code, look it up: Navien Air Conditioner codes
More other tips for air conditioner
Source: Navien NAA air conditioner service manual, pp. 9-10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.