Navien Air Conditioner: Brazing and ventilation rules
Brazing and ventilation rules on a Navien air conditioner: Brazing and refrigerant work need open or well-ventilated space, and only brazed joints are acceptable on existing lines.
Applies to: NAA17V36-24K/36K, NAA17V60-48K/60K
How to fix brazing and ventilation rules: step by step
- Make sure the area is open or adequately ventilated before opening the system or brazing.
- Do not work in confined spaces.
- Only braze lines that are open to the atmosphere or properly exhausted.
- On existing refrigerant lines, confirm all joints are brazed, not soldered.
- Use a quenching cloth for brazing and keep a dry powder or CO2 extinguisher nearby.
If the unit shows an error code, look it up: Navien Air Conditioner codes
More other tips for air conditioner
Source: Navien Air Conditioner NAA Series Service Manual, p. 6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.