Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Tankless RX temperature settings available

Updated · by Aurora Star Tech Inc.

Rinnai Tankless RX temperature settings available: reference table for the tankless water heater (SENSEI RX/CX series): a quick-reference table with notes.

Tankless Water HeaterInstaller menu / Control settingsSENSEI RX/CX

Rinnai Tankless RX temperature settings available table

FCNote
9837-
10038-
10239-
10440Default after power loss if unit was powered under 6 h
10641-
10842-
11043Highest setting while hot water is flowing
11546-
12049Default max; crossover mode minimum
12552Needs parameter 01b
13054Needs parameter 01b
13557Needs parameter 01b
14060Needs parameter 01b

How to use the Rinnai Tankless RX temperature settings available table

Find your exact model in the first column and read across the row. Values in the Rinnai Tankless RX temperature settings available table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • While hot water is running the setting can only be changed between 98 F and 110 F (37-43 C).
  • Switch F/C: hold On/Off 5 s with the heater off. Outdoor units auto-lock the controller after 30 min idle.

Applies to: RX199i, RX180i, RX160i, RX130i, RXP199i, RXP160i (indoor)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models this applies to

RX130iRX160iRX180iRX199iRXP160iRXP199i

Rinnai Tankless Water Heater error codes →

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 29 Temperature Settings, p.57-58. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.