Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Tankless RSC clearances to combustibles

Updated · by Aurora Star Tech Inc.

Rinnai Tankless RSC clearances to combustibles: reference table for the tankless water heater (SENSEI series): a quick-reference table with notes.

Tankless Water HeaterClearancesSENSEI

Rinnai Tankless RSC clearances to combustibles table

LocationClearance
Top2 in. (51 mm); 0 in. from vent components
Bottom/ground12 in. (305 mm)
Front0 in.; 24 in. (610 mm) service clearance
Back0 in.
Sides2 in. (51 mm); add 0.25 in. (6.35 mm) for recess box
Vent0 in.
Front exhaust (outdoor models)24 in. (610 mm)

How to use the Rinnai Tankless RSC clearances to combustibles table

Find your exact model in the first column and read across the row. Values in the Rinnai Tankless RSC clearances to combustibles table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Same values apply to combustible and non-combustible surfaces.

Applies to: RSC199i, RSC160i (indoor); RSC199e, RSC160e (outdoor)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models this applies to

RSC160eRSC160iRSC199eRSC199i

Rinnai Tankless Water Heater error codes →

Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 6 Clearances, p.22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.