Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Tankless RUCS/RUS unit clearances

Updated · by Aurora Star Tech Inc.

Rinnai Tankless RUCS/RUS unit clearances: reference table for the tankless water heater (Non-SENSEI series): a quick-reference table with notes.

Tankless Water HeaterClearancesNon-SENSEI

Rinnai Tankless RUCS/RUS unit clearances table

LocationRUCS indoor to combustiblesRUCS indoor to non-combustiblesRUS outdoor to combustiblesRUS outdoor to non-combustibles
Top6 in. (152 mm) *2 in. (51 mm) *12 in. (305 mm)2 in. (51 mm)
Back0 in.0 in.0 in.0 in.
Front6 in. (152 mm)6 in. (152 mm)--
Front (panel)--24 in. (610 mm)0 in.
Front (exhaust)--24 in. (610 mm)24 in. (610 mm)
Sides2 in. (51 mm)1/2 in. (13 mm)6 in. (152 mm)1/8 in. (3.2 mm)
Ground/bottom12 in. (305 mm)12 in. (305 mm)12 in. (305 mm)2 in. (51 mm)
Vent0 in.0 in.--

How to use the Rinnai Tankless RUCS/RUS unit clearances table

Find your exact model in the first column and read across the row. Values in the Rinnai Tankless RUCS/RUS unit clearances table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • 0 in. from vent components and condensate drain line.
  • Service clearance 24 in. in front of the heater; closet installs need 6 in. (152 mm) in front.
  • RUCS models are indoor only and RUS models are outdoor only.

Applies to: RUCS65i, RUCS75i (indoor); RUS65e, RUS75e (outdoor)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models this applies to

C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94eV94iV94Xi

Rinnai Tankless Water Heater error codes →

Source: Rinnai KCM Series (RUCS/RUS) Installation and Operation Manual (U328-0700X04(00)), Unit clearances, p.10. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.