Allied Error Code 1 flash: Flame sensed with gas valve off (Furnace)

Updated · by Aurora Star Tech Inc.

Allied error code 1 flash on a furnace means: Flame sensed with gas valve off. It is also called Allied diagnostic code 1 flash.

Critical severityFurnaceA95/A93/95G1/92G1UH · A95/95G1UH · A93/92G1UH

Homeowner? What Allied code 1 flash means for you

Stop and call Your furnace is reporting: Flame sensed with gas valve off. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Allied error code 1 flash mean?

The control sees flame while the gas valve is supposed to be closed. Code listed only in the manual; no causes or steps given.

Applies to: A95UH, A93UH, 95G1UH, 92G1UH (sizes 045-08 to 135-20)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Allied models that use code 1 flash

92G1UH92G1UH0450892G1UH0451292G1UH0700892G1UH0701292G1UH0901292G1UH0901692G1UH1101692G1UH1102092G1UH1352095G1UHA93UHA93UH1DA95UHA95UH1D

Other Allied Furnace codes

CodeMeaning
2 flashesPressure switch closed with inducer off
3 flashesPressure switch open with inducer on
4 flashesHigh limit switch open
5 flashesRollout switch open
6 flashesPressure switch cycle lockout
7 flashesLockout - no ignition
8 flashesLockout - too many flame dropouts
9 flashesIncorrect line voltage phasing
LED offNo power to control or control hardware fault
LED onNormal operation

All Allied Furnace error codes →

Allied code 1 flash: homeowner questions

What does Allied code 1 flash mean?

Flame sensed with gas valve off. The control sees flame while the gas valve is supposed to be closed. Code listed only in the manual; no causes or steps given.

Is it safe to keep using my furnace with code 1 flash?

No. Code 1 flash is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Allied code 1 flash myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Allied code 1 flash near me?

Aurora Star Tech Inc. repairs Allied furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Allied 506724-01 (Issue 1108) A95UH/A93UH/95G1UH/92G1UH Installation Instructions, Diagnostic Codes p.53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.