Allied 92G1UH09012 error codes list

CodeMeaningSeverity
1 flashFlame sensed with gas valve offCritical
2 flashesPressure switch closed with inducer offMedium
3 flashesPressure switch open with inducer onHigh
4 flashesHigh limit switch openHigh
5 flashesRollout switch openCritical
6 flashesPressure switch cycle lockoutHigh
7 flashesLockout - no ignitionHigh
8 flashesLockout - too many flame dropoutsHigh
9 flashesIncorrect line voltage phasingHigh
LED offNo power to control or control hardware faultHigh
LED onNormal operationLow

Troubleshooting the 92G1UH09012

All Allied Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.