Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Allied Furnace Error Codes

Updated · by Aurora Star Tech Inc.

11 Allied Furnace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Allied Furnace error codes list

CodeMeaningSeverity
1 flashFlame sensed with gas valve offCritical
2 flashesPressure switch closed with inducer offMedium
3 flashesPressure switch open with inducer onHigh
4 flashesHigh limit switch openHigh
5 flashesRollout switch openCritical
6 flashesPressure switch cycle lockoutHigh
7 flashesLockout - no ignitionHigh
8 flashesLockout - too many flame dropoutsHigh
9 flashesIncorrect line voltage phasingHigh
LED offNo power to control or control hardware faultHigh
LED onNormal operationLow

Find codes by Allied model

A95/A93/95G1/92G1UH

92G1UH92G1UH0450892G1UH0451292G1UH0700892G1UH0701292G1UH0901292G1UH0901692G1UH1101692G1UH1102092G1UH1352095G1UHA93UHA95UH

A93/92G1UH

A93UH1D

A95/95G1UH

A95UH1D

Furnace troubleshooting guides

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977