Allied Furnace: Remove the bottom panel for bottom or side return
Remove the bottom panel for bottom or side return on a Allied furnace: The furnace ships with the bottom panel in place. It must come out for horizontal or upflow bottom-return installs.
Applies to: Upflow with bottom return or horizontal installs
How to fix remove the bottom panel for bottom or side return: step by step
- Remove the two screws holding the bottom cap.
- Pivot the bottom cap down to release the bottom panel.
- Remove the bottom panel.
- Reinstall the bottom cap when done.
If the unit shows an error code, look it up: Allied Furnace codes
More commissioning tips for furnace
Source: Allied 92G1UH installation instructions manual, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.