Allied Furnace: Checking a shared vent after this furnace is removed or replaced

Updated · by Aurora Star Tech Inc.

Checking a shared vent after this furnace is removed or replaced on a Allied furnace: If this furnace was on a common vent with other gas appliances, the vent may now be too large for the remaining appliances. Test each remaining appliance on its own while the others stay off. Carbon monoxide poisoning can result if this test is skipped.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Furnace replacement or removal from a common vent

Common causes of checking a shared vent after this furnace is removed or replaced

  • Vent sized for the old furnace plus other appliances
  • Blockage, restriction, leakage, corrosion or poor horizontal pitch in the vent

How to fix checking a shared vent after this furnace is removed or replaced: step by step

  1. Seal any unused openings in the common vent.
  2. Inspect the vent for correct size, horizontal pitch, blockage, leakage and corrosion.
  3. Close building doors, windows and doors to other spaces. Run clothes dryers and non-vented appliances, and run bathroom and range hood exhausts at full speed. Do not run a summer exhaust fan. Close fireplace dampers.
  4. Light the appliance being checked and set the thermostat so it runs continuously.
  5. After the main burner has run 5 minutes, check for flue gas leaks at the draft hood relief opening with a match or candle flame.
  6. Return doors, windows, fans, dampers and other appliances to their previous operation.
  7. If a venting problem is found, resize the common vent to the minimum size from the tables in Appendix G of ANSI Z223.1 (National Fuel Gas Code).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Allied Furnace codes

Source: Allied 92G1UH installation manual, p. 41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.