Allied Furnace: Gas valve pressure testing

Updated · by Aurora Star Tech Inc.

Gas valve pressure testing on a Allied furnace: The gas valve can be damaged by test pressure.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Gas valve

How to fix gas valve pressure testing: step by step

  1. Disconnect and isolate the gas valve before pressure testing the line.
  2. Do not test above 1/2 psig (3.48 kPa) at the valve.
  3. Use the 1/8 in NPT plugged tap on the valve for gauge connection.
  4. If the manual main shut-off valve will not hold test pressure, use the isolation method shown in Figure 48.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Allied Furnace codes

Models

92G1UH92G1UH0450892G1UH0451292G1UH0700892G1UH0701292G1UH0901292G1UH0901692G1UH1101692G1UH1102092G1UH1352095G1UHA93UHA95UH

More commissioning tips for furnace

Source: Allied 92G1UH installation instructions manual, p. 35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977