NaviCirc: leak, poor operation or noise right after install on a Navien tankless water heater: Most problems right after a NaviCirc install come from the hose connections, air left in the lines, or the valve being forced against the wall.
Applies to: NaviCirc recirculation valve (PFFW-SXX-001) on Navien NPE-A/A2/S2, NPN water heaters and NCB-H/NFC-H combi boilers
Common causes of navicirc: leak, poor operation or noise right after install
- Teflon tape or sealant used on the 1/2 in male ports, or hoses without rubber gaskets
- Air purge too short
- Valve mounted crooked or anchors over-tightened
- Shutoff valves left closed
How to fix navicirc: leak, poor operation or noise right after install: step by step
- Warning: both hot and cold shutoff valves must be open whenever the NaviCirc is in use. Running it with the valves closed builds hot water pressure and can hurt someone.
- Leak: close the shutoff valves first, then fix the connection. Do not use Teflon tape or adhesive on the NaviCirc 1/2 in male ports. Use hoses with rubber gaskets.
- Hose layout: faucet hoses go to HOT OUT / COLD OUT, the supply hoses from the shutoff valves go to HOT IN / COLD IN (3/8 to 1/2 in adapters as needed).
- Purge air: open both hot and cold faucets and let them run long enough to clear all air. A short purge can stop the valve from working and air can damage the pump.
- Mounting: it must sit level (horizontal) and be fixed with the 3 supplied anchors. Do not crank the anchors down hard, it can damage the valve.
- Limits: max 150 psi, water 41-180 F, indoor only, room 32-122 F.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Source: Navien NaviCirc Installation and Operation Manual (navicirc-installation-and-operation-manual-en.pdf), p.6, 9-13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.