Navien Tankless Water Heater: NaviCirc: lukewarm water when the cold tap is first opened
NaviCirc: lukewarm water when the cold tap is first opened on a Navien tankless water heater: With a NaviCirc there is no return line, so the cold line is used as the return. A little warm water in the cold line is expected. The valve closes the hot-to-cold crossover at about 95 F (35 C).
Applies to: NaviCirc recirculation valve (PFFW-SXX-001) on Navien NPE-A/A2/S2, NPN water heaters and NCB-H/NFC-H combi boilers
Common causes of navicirc: lukewarm water when the cold tap is first opened
- Normal operation of the crossover valve: cold line carries recirculated water
- Possible valve problem if it does not stop at about 95 F (see section 3 of the manual)
How to fix navicirc: lukewarm water when the cold tap is first opened: step by step
- Tell the customer that lukewarm water for a moment when they first open the cold tap is normal with this setup.
- The valve shuts the crossover at about 95 F (35 C). Valve flow range is 0.53-1.06 GPM (2-4 L/min).
- Check the heater set temperature and recirc mode are correct (see the 'far faucet slow' guide).
- If hot water keeps coming out of the cold tap, check the manual's troubleshooting table, section 3 p.86, before replacing the valve.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Source: Navien NaviCirc Installation and Operation Manual (navicirc-installation-and-operation-manual-en.pdf), p.5-6, 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.