Navien Tankless Water Heater: E434 flow regulating valve fault on NHW700

Updated · by Aurora Star Tech Inc.

E434 flow regulating valve fault on NHW700 on a Navien tankless water heater: No feedback from the flow regulating (water adjustment) valve for over 10 seconds while it is fully open. Sub code 1 = open, 2 = close. Alarm only.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of e434 flow regulating valve fault on nhw700

  • Loose valve plug
  • Valve stuck or failed
  • No supply from the PCB

How to fix e434 flow regulating valve fault on nhw700: step by step

  1. Power off before unplugging connectors or measuring resistance.
  2. Cycle power to the heater.
  3. Reseat the valve plug.
  4. Check supply: 12 V DC blue P3-P1 and P6-P1. Position signal blue P2-P1 0-5 V DC changes as the valve moves. Drive pulses on P4, P5, P7, P8.
  5. Supply good but valve does not move or reads wrong: replace the valve (measure its resistance first).
  6. No supply: replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.13 p.108, 7.2 p.91, 5.5 p.74. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977