Navien Tankless Water Heater: E407 / E421 / E441 thermistor codes on NHW700
E407 / E421 / E441 thermistor codes on NHW700 on a Navien tankless water heater: On the NHW700: E407 = hot water outlet thermistor, E421 = direct water thermistor, E441 = heat exchanger outlet thermistor. Sub code 1 = open, 2 = shorted. Auto reset. Note: E421 and E441 mean different sensors on the NPE-2.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
Common causes of e407 / e421 / e441 thermistor codes on nhw700
- Broken or unplugged thermistor wire
- Shorted wiring
- Failed thermistor
- PCB fault
How to fix e407 / e421 / e441 thermistor codes on nhw700: step by step
- Power off before unplugging connectors or measuring resistance.
- Read the sub code (1 open, 2 short) in the error history.
- Check the wire and plug of that sensor. Reconnect it.
- Measure the sensor resistance with the sensor cool. Bad reading or broken wire: replace the thermistor.
- Find and repair any shorted wiring.
- With power on, the sensor signal at the PCB should be 0-5 V DC and change with temperature (inlet P13-P14, outlet 2 P11-P12, outlet 1 P9-P10).
- Sensor good and code stays: replace the PCB.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.1 p.88, 7.3.11-7.3.14 p.106-109, 5.7 p.77, 5.5 p.75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.