Navien Tankless Water Heater: Hot water is cold or turns cold
Hot water is cold or turns cold on a Navien tankless water heater: Hot water faucet runs cold or goes cold and stays cold.
Applies to: NPE water heaters
Common causes of hot water is cold or turns cold
- Clogged cold water inlet filter
- Hot water faucet not open far enough (less than 2 LPM through the heater)
- Error code on front panel
- Missing check valve on external recirculation return line
How to fix hot water is cold or turns cold: step by step
- Clean the cold water inlet filter (see the Operation manual, section 4.4).
- Open the hot water faucet fully and confirm at least 2 LPM flows through the heater.
- Check the front panel for an error code and refer to the Error Code Guide.
- If an external recirculation system is installed, confirm a check valve is on the return line.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Source: Navien NPE remote controller manual, p. 29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.