E016 / E046 overheating and high limit switch on NHW700 on a Navien tankless water heater: E016: the heat exchanger high limit opened while firing (manual reset). E046: the high limit signal stayed on for over 15 seconds, or was seen before firing or during post-purge (auto reset when the signal clears). The high limit is there to stop the burner if the heat exchanger goes over 96 C (205 F).

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of e016 / e046 overheating and high limit switch on nhw700

  • Scale in the heat exchanger
  • Wrong capacity DIP switch setting
  • High-stage gas pressure set too high
  • Hot water thermistor reading low
  • Bad high limit switch or open thermal fuse
  • Loose wiring between high limit, thermal fuse and PCB
  • PCB fault

How to fix e016 / e046 overheating and high limit switch on nhw700: step by step

  1. Gas unit: only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
  2. E016: turn the heater off for at least 30 minutes, then restart. Clean the inlet filter and check all valves are open.
  3. Check the capacity DIP switches (DIP 2) match the model.
  4. Check the high-stage gas pressure setting.
  5. Check the hot water thermistor resistance. A sensor reading low makes the heater overfire.
  6. Let the heat exchanger outlet cool below 96 C (205 F). Unplug the high limit and check continuity across its pins. No continuity: replace it.
  7. Unplug the thermal fuse and measure it: 0.1-0.3 ohm is good, OL means open, replace it.
  8. Check the wiring from high limit and thermal fuse to the PCB.
  9. Listen for boiling and look for cracks or soot on the heat exchanger. Heavy scale: descale or replace.
  10. The table also lists E031 (burner overheat): check the burner fuse.
  11. Still there: replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.4 p.99, 7.3.5 p.100, 7.2 p.90, 5.1 p.70, 5.6 p.76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.