Navien Tankless Water Heater: NHW700 error history, sub codes and resets
NHW700 error history, sub codes and resets on a Navien tankless water heater: How to read the last 10 errors with their sub code and how reset works.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
Common causes of nhw700 error history, sub codes and resets
- Lock-out errors need a manual reset or power off/on
- Auto reset errors clear when the problem clears
How to fix nhw700 error history, sub codes and resets: step by step
- From normal or error display, hold the Information button 2 seconds. Error 0 is the newest; Up/Down scroll through 10.
- Press Information to switch between hours since the previous error (max 9999) and the sub code.
- Hold Reset 5 seconds in history mode to clear it (CLR shows). Press Reset once to go back.
- Diagnostics button once shows the service information list.
- In lock-out the heater only restarts after reset or power off/on. After an error clears the fan stops for 10 seconds.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 4.11 p.64, 4.12 p.65, 6.3 p.87. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.