Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Error Code Drain light flashing green: Preparing to drain (General)

Updated · by Aurora Star Tech Inc.

Trane error code Drain light flashing green on a general means: Preparing to drain. It is also called Trane diagnostic code Drain light flashing green.

Low severityGeneralTrane steam humidifier EHUMD800

Homeowner? What Trane code Drain light flashing green means for you

Usually minor Your heating or cooling system is reporting: Preparing to drain. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Trane error code Drain light flashing green mean?

Fill valve is open to cool the water before draining. Happens when the unit is turned off, at end-of-season drain (72 hours with no call), and at forced drain after 168 hours without a drain. Also flashes during the valve pulsing described above.

Applies to: EHUMD800ASM00BA, EHUMD800BSMLCBA

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Trane models that use code Drain light flashing green

EHUMD800ASM00BAEHUMD800BSMLCBA

Other Trane General codes

CodeMeaning
Drain light solid greenDraining canister
Fill light flashing greenPulsing valves to clear mineral build-up
Fill light solid greenFilling canister
Fill light solid redCanister cannot fill, humidifier shut down
On/Off light flashing greenStart-up delay after power restored
On/Off light solid greenHumidifier on
Service light flashing redCanister at end of life
Service light solid redOver-current fault, humidifier shut down
Steam light solid greenMaking steam, normal
Steam light solid yellowNot making rated steam output

All Trane General error codes →

Trane code Drain light flashing green: homeowner questions

What does Trane code Drain light flashing green mean?

Preparing to drain. Fill valve is open to cool the water before draining. Happens when the unit is turned off, at end-of-season drain (72 hours with no call), and at forced drain after 168 hours without a drain. Also flashes during the valve pulsing…

Is it safe to keep using my heating or cooling system with code Drain light flashing green?

Usually yes. Code Drain light flashing green is normally minor, but if it keeps coming back have it checked.

Can I reset Trane code Drain light flashing green myself?

You can try one reset (power off for 30 seconds, then on). If Trane code Drain light flashing green comes back, the cause is still there and a licensed technician should check it.

Who can fix Trane code Drain light flashing green near me?

Aurora Star Tech Inc. repairs Trane heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Trane steam humidifier owner's manual 32-5092-3A, Display Panel, Table 1, PDF p.8-9 (printed p.8-9). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977