Trane General: XR724 says heating or cooling but no air at the registers
XR724 says heating or cooling but no air at the registers on a Trane general: The display shows Heating or Cooling but no air comes out of the vents.
Applies to: Trane XR724 touchscreen comfort control TCONT724AS42DA (also sold under American Standard)
Common causes of xr724 says heating or cooling but no air at the registers
- Blower on-delay has not finished
- Equipment problem (blower, board, wiring)
How to fix xr724 says heating or cooling but no air at the registers: step by step
- Wait one minute for the blower on-delay to finish, then check the registers again.
- Still no air: check the blower and board at the indoor unit. Use Test Mode > Blower to energize G (and BK at 50 % or 100 % on variable speed) and see if the blower runs.
- On a variable speed indoor unit, check how BK is wired. The wiring diagrams in this guide say to cut the factory BK jumper at the indoor unit when BK is run from the XR724.
If the unit shows an error code, look it up: Trane General codes
Source: Trane XR724 Comfort Control (TCONT724AS42DA) User Guide and Installer's Guide 18-HD82D1-1E-EN, Troubleshooting p.38 and Test Mode p.8, Field Wiring Diagrams p.20-36. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.