Trane General: Humidifier not making steam
Humidifier not making steam on a Trane general: Basic checks when the humidifier will not produce steam.
Applies to: EHUMD800ASM00BA, EHUMD800BSMLCBA
Common causes of humidifier not making steam
- Humidifier switched off
- Water saddle valve closed
- Indoor blower not running
- Humidity control not calling
How to fix humidifier not making steam: step by step
- Turn off power before opening the cabinet.
- Confirm the humidifier is on and the green On/Off light is lit.
- Confirm the water saddle valve is open.
- Confirm the indoor blower is running. The humidifier will not run without it.
- Turn the humidity control to its maximum RH setting to force a call, then lower it to the recommended setting for the outdoor temperature.
- Look at the lights. Solid red Fill or Service light means a fault, see those code entries.
If the unit shows an error code, look it up: Trane General codes
Models
EHUMD800ASM00BAEHUMD800BSMLCBA
Source: Trane steam humidifier owner's manual 32-5092-3A, Check the Humidifier Operation, PDF p.10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.