Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code LF: Compressor speed held back by current (AC)

Updated · by Aurora Star Tech Inc.

Navien error code LF on a air conditioner means: Compressor speed held back by current. It is also called Navien diagnostic code LF.

Low severityAir ConditionerAlso Heat PumpNavien NAA

Homeowner? What Navien code LF means for you

Usually minor Your air conditioner is reporting: Compressor speed held back by current. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code LF mean?

Status only. The board is limiting compressor speed because of current. Nothing is broken.

Applies to: NAA17V36 (24K/36K), NAA17V60 (48K/60K)

Common causes of Navien code LF

  • Normal protection: current near its limit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code LF

NAA17V36NAA17V60

Other Navien AC codes

CodeMeaning
L1DC bus voltage too high
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LECompressor speed held back by drive module temperature
LOCharging mode: outdoor air too cold
P1High pressure switch opened
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Condenser coil (T3) temperature too high - cooling

All Navien Air Conditioner error codes →

Navien code LF: homeowner questions

What does Navien code LF mean?

Compressor speed held back by current. Status only. The board is limiting compressor speed because of current. Nothing is broken.

Is it safe to keep using my air conditioner with code LF?

Usually yes. Code LF is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code LF myself?

You can try one reset (power off for 30 seconds, then on). If Navien code LF comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code LF near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA Series Air Conditioner Service Manual, 3.2.20, p.44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977