Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

NTI Error Code 02 01: Damaged or shorted DHW temperature probe (Boiler)

Updated · by Aurora Star Tech Inc.

NTI error code 02 01 on a boiler means: Damaged or shorted DHW temperature probe. It is also called NTI diagnostic code 02 01.

Medium severityBoilerTRX

Homeowner? What NTI code 02 01 means for you

Check, then call Your boiler is reporting: Damaged or shorted DHW temperature probe. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does NTI error code 02 01 mean?

Applies to Combi models only. The controller uses the boiler return sensor in place of the DHW outlet sensor and keeps running CH and DHW.

Applies to: TRX150 (Combi models)

Common causes of NTI code 02 01

  • Damaged or shorted DHW outlet probe
  • Loose wiring
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

NTI models that use code 02 01

TRX085TRX110CTRX150TRX199TRX199C

Other NTI Boiler codes

CodeMeaning
1 12CH return temperature probe open or short circuit
1 14External (outdoor) sensor open or short circuit
1 16Floor thermostat contact open
1 P1Insufficient circulation or missing water (warning)
1 P2Insufficient circulation or missing water (warning)
1 P3Inadequate circulation or missing water (warning)
02 03Storage temperature probe open or short circuit
02 05DHW inlet probe open circuit
02 09Storage overheating
2 P2Anti-Legionella function not completely finished
03 01Display EEPROM error
03 02Communication error GP-GIU

All NTI Boiler error codes →

NTI code 02 01: homeowner questions

What does NTI code 02 01 mean?

Damaged or shorted DHW temperature probe. Applies to Combi models only. The controller uses the boiler return sensor in place of the DHW outlet sensor and keeps running CH and DHW.

Is it safe to keep using my boiler with code 02 01?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset NTI code 02 01 myself?

You can try one reset (power off for 30 seconds, then on). If NTI code 02 01 comes back, the cause is still there and a licensed technician should check it.

Who can fix NTI code 02 01 near me?

Aurora Star Tech Inc. repairs NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: NTI TRX150 manual, p. 91. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair