NTI Boiler: Piping without an external central heating circulator (TRX150 / TRX199 and TRX199C)

Updated · by Aurora Star Tech Inc.

Piping without an external central heating circulator (TRX150 / TRX199 and TRX199C) on a NTI boiler: Experienced guys will tell you this layout works but has limits. The boiler's internal circulator feeds the heating system directly, so there's no external central heating pump. It suits zone valve or non-circulator systems with small flow needs, up to about 9 gpm at 9 ft of head. Go past that and you starve the heat exchanger, so confirm the numbers first.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: TRX150 / TRX199 / TRX199C without external central heating circulator

Common causes of piping without an external central heating circulator (trx150 / trx199 and trx199c)

  • Zone valve system with low flow needs
  • Job with no space or budget for an external circulator
  • High-resistance or long piping that exceeds the internal pump's capability
  • System needing primary/secondary piping instead

How to fix piping without an external central heating circulator (trx150 / trx199 and trx199c): step by step

  1. Confirm the system flow is within about 9 gpm at 9 ft of head before using this layout.
  2. For direct piping (not primary/secondary), install the expansion vessel on the return side of the boiler.
  3. Do not put check valves or other flow-restricting devices between the boiler return and the expansion vessel.
  4. Keep minimum flow of 2 gpm through the heat exchanger.
  5. Keep the 12-diameter straight-pipe run upstream of any circulator.
  6. Check flow after startup by comparing supply and return temperatures.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: NTI Boiler codes

Models

TRX085TRX110CTRX150TRX199TRX199C

Source: NTI TRX150 manual, p. 33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.