Gas leak check before startup on a NTI boiler: First thing I do on any gas appliance startup is use my nose. Before and during the first start, smell at the floor and around the boiler. If there is any sign of a gas leak, do not start it. Propane is the one that fools people, because the odorant can fade in a tank or new piping and you may smell nothing even with gas present. That is why the supplier should verify the odorant level, not you guessing.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: TRX boilers on natural gas or propane

Common causes of gas leak check before startup

  • Gas leak at fittings, unions or valves from install or handling
  • Propane odorant level too low, so a leak goes unnoticed
  • Loose connection disturbed during boiler setup
  • Damaged flex connector or gas valve seal

How to fix gas leak check before startup: step by step

  1. Smell near the floor and around the boiler before startup, since propane sinks.
  2. Remove the front door and smell inside the enclosure.
  3. If a leak is suspected, shut the boiler down at once, leave the area and do not operate switches or flames.
  4. Find the leak with a bubble test and repair it before restarting.
  5. Only licensed gas technicians should repair gas connections.
  6. For propane, have the supplier confirm the odorant level before startup and periodically after.
  7. Recheck every joint with leak solution after the repair, then start again and recheck at full fire.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: NTI Boiler codes

Models

TRX085TRX110CTRX150TRX199TRX199C

Source: NTI TRX150 manual, p. 80. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977