NTI Boiler: Canada vent installation requirements
Canada vent installation requirements on a NTI boiler: Extra requirements for Canadian installations.
Applies to: Canadian installations
How to fix canada vent installation requirements: step by step
- Use a vent system certified to ULC-S636.
- Keep the first 3 ft of vent pipe from the flue outlet readily accessible for inspection.
- Do not mix components with other vent systems or unlisted pipe or fittings.
- Keep plastic vent and boiler parts at least 8 in from high heat sources (100 F / 37 C or greater).
If the unit shows an error code, look it up: NTI Boiler codes
Models
TRX085TRX110CTRX150TRX199TRX199C
Source: NTI TRX150 manual, p. 35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.