Rheem Error Code 93: Internal control fault (Furnace)

Updated · by Aurora Star Tech Inc.

Rheem error code 93 on a furnace means: Internal control fault. It is also called Rheem diagnostic code 93.

Critical severityFurnaceRheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC) · R95P · RGPE/RGLE

Homeowner? What Rheem code 93 means for you

Stop and call Your furnace is reporting: Internal control fault. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rheem error code 93 mean?

Internal furnace control fault. 802P/R95P: hard lockout - internal fault, or voltage on the gas valve contacts (welded relay) that does not clear when the inducer cycles; cycling the heat call will not reset it. RGPE/RGLE: CONTROL FLT, Call For Service. 802P manual lists 93 in the flowchart but not the main fault table.

Applies to: 802P/80MDP (802PA050-150); R95P (R95PA040-115); RGPE/RGLE 2-stage 80+

Common causes of Rheem code 93

  • IFC internal failure
  • Gas valve relay welded
  • Miswiring feeding voltage to the gas valve circuit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rheem models that use code 93

Show all 21 models

R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSARGLE-05(-)BMKRRGLE-07(-)AMKRRGLE-07(-)BRQRRGLE-10(-)BRMRRGLE-12(-)ARMRRGPE-05(-)BMKRRGPE-07(-)AMKRRGPE-07(-)BRQRRGPE-10(-)BRMRRGPE-12(-)ARMR

Other Rheem Furnace codes

CodeMeaning
59Water sensed / blocked drain
60Blower fault - running (BLWR FLT-RUN)
61Blower fault - blower not running
66Blower overspeed (BLOWER OVRSPEED)
68No blower communication (NO BLWR COMM)
82Supply air sensor fault (SA SENSOR FLT)
d1No shared data (NO SHARED DATA)
d4Memory card invalid (MEM CARD INVALD)
d5Card/hardware conflict (CARD-HRD CNFLCT)
d6Blower HP conflict (BLWR HP CNFLCT)
d7Blower manufacturer conflict (BLWR MFG CNFLCT)
d8Old shared data (OLD SHARED DATA)

All Rheem Furnace error codes →

Rheem code 93: homeowner questions

What does Rheem code 93 mean?

Internal control fault. Internal furnace control fault. 802P/R95P: hard lockout - internal fault, or voltage on the gas valve contacts (welded relay) that does not clear when the inducer cycles; cycling the heat call will not reset it. RGPE/RGLE: CONTROL FLT…

Is it safe to keep using my furnace with code 93?

No. Code 93 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Rheem code 93 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Rheem code 93 near me?

Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: 802P: 92-24161-146-02, Lockout / Diagnostics Flowchart, p.41, 51; R95P: Lockout section, p.88 (PDF p.92); RGPE/RGLE: Table 16 p.49 / Table 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.