Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code ST.30: Normal operation (AC)

Updated · by Aurora Star Tech Inc.

Navien error code ST.30 on a air conditioner means: Normal operation. It is also called Navien diagnostic code ST.30.

Low severityAir ConditionerNavien NAE

Homeowner? What Navien code ST.30 means for you

Usually minor Your air conditioner is reporting: Normal operation. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code ST.30 mean?

Display state: unit is running normally. Shown solid on the segment display.

Applies to: NAE28V3622A1, NAE28V6022A1

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code ST.30

NAE28V3622A1NAE28V6022A1

Other Navien AC codes

CodeMeaning
R884Inverter minor: Compressor current limit minor
R885Inverter minor: AC over voltage
R886Inverter minor: PFC overcurrent
R887Inverter minor: Input current limit
ST.10Standby
ST.20Initial startup
ST.40Post-stop delay
THCharging mode: no thermostat call

All Navien Air Conditioner error codes →

Navien code ST.30: homeowner questions

What does Navien code ST.30 mean?

Normal operation. Display state: unit is running normally. Shown solid on the segment display.

Is it safe to keep using my air conditioner with code ST.30?

Usually yes. Code ST.30 is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code ST.30 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code ST.30 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code ST.30 near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAE I&O manual (07/2026), 3.2 LCD screen display, p.32-33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977