Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code A255: Alarm: CUR overcurrent protection (AC)

Updated · by Aurora Star Tech Inc.

Navien error code A255 on a air conditioner means: Alarm: CUR overcurrent protection. It is also called Navien diagnostic code A255.

Medium severityAir ConditionerNavien NAE

Homeowner? What Navien code A255 means for you

Check, then call Your air conditioner is reporting: Alarm: CUR overcurrent protection. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code A255 mean?

Unit stops, then restarts by itself after a delay (auto reset). Repeats lead to error E205 (display shows 255).

Applies to: NAE28V3622A1, NAE28V6022A1

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code A255

NAE28V3622A1NAE28V6022A1

Other Navien AC codes

CodeMeaning
A251Alarm: PD high pressure protection
A252Alarm: PS low pressure protection
A253Alarm: TD discharge temperature protection
A254Alarm: CR compression ratio protection
A256Alarm: heatsink protection
A257Alarm: compressor temperature abnormal protection
A258Alarm: TS suction temperature protection
A259Alarm: superheat protection
A260Alarm: high pressure switch (HPS) protection
A851Inverter trip alarm: Communication error
A852Inverter trip alarm: Compressor current sensor error
A853Inverter trip alarm: DC link sensor error

All Navien Air Conditioner error codes →

Navien code A255: homeowner questions

What does Navien code A255 mean?

Alarm: CUR overcurrent protection. Unit stops, then restarts by itself after a delay (auto reset). Repeats lead to error E205 (display shows 255).

Is it safe to keep using my air conditioner with code A255?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code A255 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code A255 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code A255 near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAE I&O manual (07/2026), 7.1 Alarm table and 7.2, p.40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977