Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code ATL: Outdoor temperature outside operating range (AC)

Updated · by Aurora Star Tech Inc.

Navien error code ATL on a air conditioner means: Outdoor temperature outside operating range. It is also called Navien diagnostic code ATL.

Medium severityAir ConditionerNavien NAA

Homeowner? What Navien code ATL means for you

Check, then call Your air conditioner is reporting: Outdoor temperature outside operating range. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code ATL mean?

The T4 outdoor sensor reads outside the operating range (5 to 125°F (-15 to 52°C)). The unit waits.

Applies to: NAA17V36 (24K/36K), NAA17V60 (48K/60K)

Common causes of Navien code ATL

  • Real outdoor temperature outside the range
  • T4 sensor reading wrong
  • PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code ATL

NAA17V36NAA17V60

Other Navien AC codes

CodeMeaning
A869Inverter trip alarm: AC over voltage
A870Inverter trip alarm: PFC unbalanced current
A871Inverter trip alarm: Fan motor error (5 min)
A872Inverter trip alarm: Discharge FET error
A873Inverter trip alarm: Stator overheat (5 min)
A874Inverter trip alarm: PBA (power board) over temperature
d0Oil return cycle
dCForced cooling
E201High pressure (PD) protection error
E202Low pressure (PS) protection error
E203Compressor discharge temperature (TD) protection error
E204Compression ratio (CR) protection error

All Navien Air Conditioner error codes →

Navien code ATL: homeowner questions

What does Navien code ATL mean?

Outdoor temperature outside operating range. The T4 outdoor sensor reads outside the operating range (5 to 125°F (-15 to 52°C)). The unit waits.

Is it safe to keep using my air conditioner with code ATL?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code ATL myself?

You can try one reset (power off for 30 seconds, then on). If Navien code ATL comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code ATL near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA Series Air Conditioner Service Manual, 3.2.21, p.45. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977