NTI TRX150 Error Codes

Updated · by Aurora Star Tech Inc.

NTI TRX150 error codes and diagnostic codes. The TRX150 is a NTI boiler in the TRX series.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

NTI TRX150 error codes list

CodeMeaningSeverity
01 01Overheat (CH circuit)Critical
01 03Insufficient circulation or low water pressureHigh
01 04Insufficient circulation or low water pressureHigh
01 05Insufficient circulation or low water pressureHigh
01 06Insufficient circulation or low water pressureHigh
01 07Insufficient circulation or waterHigh
01 08Low water pressure lockout (water pressure switch)Medium
1 10CH flow temperature probe open or short circuitHigh
1 12CH return temperature probe open or short circuitHigh
1 14External (outdoor) sensor open or short circuitMedium
1 16Floor thermostat contact openMedium
1 P1Insufficient circulation or missing water (warning)Low
1 P2Insufficient circulation or missing water (warning)Low
1 P3Inadequate circulation or missing water (warning)Low
02 01Damaged or shorted DHW temperature probeMedium
02 03Storage temperature probe open or short circuitMedium
02 05DHW inlet probe open circuitMedium
02 09Storage overheatingHigh
2 P2Anti-Legionella function not completely finishedLow
03 01Display EEPROM errorHigh
03 02Communication error GP-GIUHigh
03 03PCB internal errorHigh
03 04Too many resets in 15 minutes (more than 5)High
03 05PCB internal errorHigh
03 06PCB internal errorHigh
03 07PCB internal errorHigh
03 09Gas relay check failedHigh
3 P9Scheduled maintenance: call for serviceLow
4 11Room sensor open or short circuit, Zone 1Medium
4 12Room sensor open or short circuit, Zone 2Medium
4 13Room sensor open or short circuit, Zone 3Medium
4 30Detected accessory wired to BUS connectionLow
4 31Code 431 (no description printed)Low
05 01Ignition lockout after 3 failed attemptsHigh
05 02Flame detected with gas valve closedHigh
05 0410 flame lifts in one operating cycleHigh
5 P11st ignition failedHigh
5 P22nd ignition failedHigh
5 P3Flame loss during runHigh
5 P63rd and 4th ignition failedHigh
06 02Exhaust temperature above 204 °F (96 °C)Critical
06 03APS openHigh
06 05Exhaust NTC circuit open or short circuitMedium
6 12Insufficient fan speedHigh
EMERGIncorrect wiring to BUS connection (emergency mode)Medium
FILL - 108Low water pressure lockoutHigh
NOAVLPCB error: boiler application not setMedium

Troubleshooting the TRX150

All NTI Boiler error codes →

Homeowner help: Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.