Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Filter sizes by casing width and filter cabinet

Updated · by Aurora Star Tech Inc.

Carrier Filter sizes by casing width and filter cabinet: reference table for the furnace (59SC6A series): a quick-reference table with notes.

FurnaceFilters59SC6A

Carrier Filter sizes by casing width and filter cabinet table

LocationSizeSide return filterBottom return filterType
Furnace casing14-3/16 in. wide16 x 25 x 3/4 in.14 x 25 x 3/4 in.Washable
Furnace casing17-1/2 in. wide(1) 16 x 25 x 3/4 in.(1) 16 x 25 x 3/4 in.Washable
Furnace casing21 in. wide(1) 16 x 25 x 3/4 in.(1) 20 x 25 x 3/4 in.Washable
Furnace casing24-1/2 in. wide(1) 16 x 25 x 3/4 in.(1) 24 x 25 x 3/4 in.Washable
Filter cabinet16 in. high(1) 16 x 25 x 3/4 in. or (1) 16 x 25 x 4-5/16 in.-Washable or media
Filter cabinet20 in. high(1) 20 x 25 x 3/4 in. or (1) 20 x 25 x 4-5/16 in.-Washable or media
Filter cabinet24 in. high(1) 24 x 25 x 3/4 in. or (1) 24 x 25 x 4-5/16 in.-Washable or media

How to use the Carrier Filter sizes by casing width and filter cabinet table

Find your exact model in the first column and read across the row. Values in the Carrier Filter sizes by casing width and filter cabinet table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Side-return filters can differ in size - measure the existing filter.
  • Every return-air inlet needs a filter.
  • Airflow over 1800 CFM needs at least a 20 x 25 in. filter.

Applies to: All 59SC6A sizes: 026M14--10, 040M14--10, 040M17--12, 060M14--12, 060M17--16, 080M17--16, 080M21--20, 100M21--20, 100M21--22, 120M24--22, 140M24--22

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models this applies to

59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

Carrier Furnace error codes →

Source: Carrier 59SC6A Installation, Start-up, Operating and Service and Maintenance Instructions (59SC6A-01SI), Table 9 Air Filter Selection and Duct Sizing, p.24 (printed p.21). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair