Rheem Error Code Flame LED rapid blink: Amber flame LED – unexpected flame (Furnace)
Rheem error code Flame LED rapid blink on a furnace means: Amber flame LED - unexpected flame. It is also called Rheem diagnostic code Flame LED rapid blink.
Homeowner? What Rheem code Flame LED rapid blink means for you
Stop and call Your furnace is reporting: Amber flame LED - unexpected flame. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rheem error code Flame LED rapid blink mean?
Amber flame LED blinking rapidly means flame is sensed when it should not be. See code 14.
Applies to: 802P/80MDP (802PA050-150); R95P (R95PA040-115); Rheem (-)GRC upflow and (-)GTC downflow/horizontal 90 Plus condensing gas furnaces (UT Electronic Controls 1012-925 / 1028-928 and Invensys ICC-H1MC7-01 IFC); Rheem 90RJ and 90TJ 90 Plus condensing gas furnaces (UT Electronic Controls 1012-925 or Invensys ICC-H1MC7-01 IFC, hot surface ignition)
Common causes of Rheem code Flame LED rapid blink
- Gas valve leaking or stuck open
- IFC gas valve relay stuck / voltage at valve with no call
- Gas valve leaking through or not shutting off
A technician checks these and 2 other possible causes on site before replacing any part.
Rheem models that use code Flame LED rapid blink
Show all 34 models
90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSAR802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSARGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJS
Other Rheem Furnace codes
All Rheem Furnace error codes →
Rheem code Flame LED rapid blink: homeowner questions
What does Rheem code Flame LED rapid blink mean?
Amber flame LED - unexpected flame. Amber flame LED blinking rapidly means flame is sensed when it should not be. See code 14.
Is it safe to keep using my furnace with code Flame LED rapid blink?
No. Code Flame LED rapid blink is a safety shutdown, so keep the furnace off until a licensed technician has checked it.
Can I reset Rheem code Flame LED rapid blink myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Rheem code Flame LED rapid blink near me?
Aurora Star Tech Inc. repairs Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blowing cold air All brands · Furnace
- No heat All brands · Furnace
- Short cycling All brands · Furnace
- Blower does not start after burners light Rheem · Furnace
- Burners go out before the heat call ends / short cycling Rheem · Furnace
- Communicating system not found / no communication Rheem · Furnace
- ECM blower does not start on heat Rheem · Furnace
- Furnace no heat - sequence troubleshooting Rheem · Furnace
- Furnace short cycles or does not hold setpoint Rheem · Furnace
- Gas valve does not shut off when heat call ends Rheem · Furnace
- Indoor blower does not start after burners light Rheem · Furnace
- Inducer (draft motor) does not start on heat call Rheem · Furnace
- Inducer does not run / does not run on low speed Rheem · Furnace
- Inducer runs 60 s then shuts off for 5 minutes, or runs continuously Rheem · Furnace
- Inducer runs 60 seconds then off for 5 minutes Rheem · Furnace
- No heat - inducer (IDM) does not start Rheem · Furnace
- No heat - POWER LED off Rheem · Furnace
- Read target airflow from the CFM LED Rheem · Furnace
- Thermostat does not hold room temperature Rheem · Furnace
Source: 802P: 92-24161-146-02, Flame Status LED, p.43, 51; R95P: Flame Status LED, p.90 (PDF p.94); Rheem (-)GRC/(-)GTC Installation Instructions 92-24161-88-00, Figure 56 IFC Troubleshooting Guide, p.54 (printed); Rheem 90RJ/90TJ Installation Instructions 92-24161-32-08, Figure 53 IFC Troubleshooting Guide, p.54 (printed p.53). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.