Indoor blower does not run - Lennox EL195UHNE on a Lennox furnace: Constant-torque ECM blower motor check on the EL195UHNE. The motor needs 120 VAC on J48 and 24 VAC (12-33 VAC) on one speed tap of J49.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: EL195UHNE

Common causes of indoor blower does not run - lennox el195uhne

  • No 120 V at the motor
  • No 24 V on the active speed tap
  • Harness fault
  • Failed motor or motor module

How to fix indoor blower does not run - lennox el195uhne: step by step

  1. WARNING: Shut off power before unplugging J48/J49.
  2. Test 1: power on, check 120 VAC across L and N (or 7A and 9A) of J48; if missing check L1 to Neutrals on the control.
  3. Test 2: thermostat on continuous fan, check 24 VAC between C of J48 (or pin 6A on 6-pin plugs) and the fan tap on J49; if missing check 24 COM to the active tap on the control.
  4. Both voltages present and motor not running right: replace the motor, or the module only on motors with 4-pin power and 5-pin signal plugs.
  5. Before fitting a new module: each motor pin to end plate more than 100k ohms, three windings equal within about 1 ohm, and the wheel spins freely.
  6. Torque module bolts to 22 in-lb; connectors face down for a drip loop.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lennox Furnace codes

Models

Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

EL296UHV

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D

Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Lennox SL280UHV

SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Lennox SL297NV

SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), C - Blower Compartment, Figures 10-17, p.15-17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.